| Operating Temperature | -40℃~+75℃,derating shall be applied when the temperature is above +55℃. |
| Relative Humidity | ≤95%RH,condensation-free |
| Cooling Method | Forced air cooled |
| Altitude | 2000m,derating should be considered when the altitude is above 2000 meters. |
| Input / Output Power | 15kW(600Vdc~750Vdc) |
| Voltage Range | 300Vdc~750Vdc |
| Current Range | 0~25A |
| Rated Current | 20A |
| Current-sharing | Unbalance Degree<±5% |
| Accuracy of Voltage Stabilization | <±0.5% |
| Accuracy of Current Stabilization | ≤±1%(The output load ranges from 20% to 100% of the rated range.) |
| Efficiency (Full Load) | > 98%(Rated Voltage 750Vdc,50%~100%Load Current;Peak Efficiency> 98.5%) |
| Input / Output Power | 15kW |
| Voltage Range | 300Vdc~860Vdc |
| Current Range | 0~25A |
| Rated Current | 20A |
| Current-sharing | UnbalanceDegree<±5% |
| Accuracy of Voltage Stabilization | <±0.5% |
| Accuracy of Current Stabilization | ≤±1%(The output load ranges from 20% to 100% of the rated range.) |
| Efficiency (Full Load) | >98%(Rated Voltage 750Vdc,50%~100%Load Current;Peak Efficiency> 98.5%) |
| Dimension | 85mm(H)×226mm(W)×395mm(D) |
| Weight | ≤10.5kg |
| Connect Method | CAN |
| MTBF | >500,000h |
| Satisfied Standards | GB/T18487、NB/T33001、NB/T33008 |